What is the current carrying capacity of 240sqmm XLPE cable?
Cable specification for 11kV 3 Core 240sqmm BS6622 cables….Technical Specification.
Cable type | Cu/XLPE/SC/SWA/PVC | |
---|---|---|
Current carrying capacity in ground (20 °C) | (A) | 513 |
Current carrying capacity in air (30 °C) | (A) | 553 |
How is cable current rating calculated?
Cable Capacity
- For Cu Wire Current Capacity (Up to 30 Sq.mm) = 6X Size of Wire in Sq.mm. Ex.
- For Cable Current Capacity = 4X Size of Cable in Sq.mm, Ex. For 2.5 Sq.mm = 4×2.5 = 9 Amp.
- Nomenclature for cable Rating = Uo/U.
- where Uo = Phase-Ground Voltage, U = Phase-Phase Voltage, Um = Highest Permissible Voltage.
What is electrical XLPE cable?
1.2.1 Description of XLPE cable XLPE is an acronym for cross linked polyethylene. XLPE is a thermosetting polymer meaning that the material (polyethylene (PE)) is cured under heat and in that process forms bonds in all directions forming a three dimensional matrix.
What is the maximum voltage that XLPE cables can withstand XLPE?
XLPE cables can withstand a maximum voltage of 130 degC.
What is the meaning of 3.5 core?
3.5-Core Cables A 3-phase system may have a neutral wire. This wire allows the 3-phase system to be used at higher voltages while it will still support lower voltage single phase loads. It is not likely in such cases that the loads will be identical, so the neutral will carry the out-of-balance current of the system.
How do you calculate maximum current rating?
What is the maximum power rating in watts of a fixed resistor which has a voltage of 12 volts across its terminals and a current of 50 milliamperes flowing through it. Given that we know the values of the voltage and current above, we can substitute these values into the following equation: P = V*I.
What is XLPE insulated power cable?
XLPE or Cross-linked polyethylene is a thermoset insulation material. Crosslinking polymers is a process which changes the molecular structure of the polymer chains so that they are more tightly bound together and this crosslinking is done either by chemical means or physical means.
What is the maximum temperature that XLPE cable can withstand?
XLPE Cable Key Benefits & Features Cables insulated with cross-linked polyethylene are a rated maximum conductor temperature of 90 degrees Celsius and an emergency rating up to 140 degrees Celsius, depending on the standard used.
Which method is used for locating cable fault?
To find the location of cable fault using the thumping method, a thumper is set to thump repeatedly and then walking along the cable route to hear the thumping sound. The higher the dc voltage applied, the louder will be the resulting thump. This method is useful for relatively shorter cables.
Why do we use 4 core cable?
Well, the main advantage of this type of cable is its conductivity. A 4 core wire delivers twice the amount of current that a two-core electrical wire carries. Understandably, a 4-conductor cable is thicker and more expensive compared to a single core or two-core wire.
How many cores does a 3 phase cable have?
4 cores
Three Phase Power Cables The three phase cables are usually circular and contain 4 cores with 3 of these being live and 1 being neutral.
How do you calculate cable size in kVA?
Full Load Current = (KVA · 1000) / (1.732 · Voltage): Full Load Current = (100 · 1000) / (1.732 · 415) = 139 Amp….Let’s select 3.5 core 95 Sq.mm cable for single run, short circuit capacity = 8.2 KA.
- Current capacity of 95 Sq.mm cable is 200 Amp,
- Total derating current of 70 Sq.mm Cable = 200 · 0.93 = 187 Amp.
What is maximum load current?
The maximum load current is the smallest amount of current in amps that must be drawn from a particular output for that output to function.
Is code for XLPE cable?
a. IS-7098, 1998 (Part-I) : Cross linked polyethylene insulated PVC sheathed cables for working voltages upto 1100V.